Stopping Continuous Measurement
Stops continuous measurement.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
1030
+3
0010
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
1030
+3
0010
+4
-
+5
-
Unit Stand-alone Test Measurement Execution
Performs a test measurement on the specified unit.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
1040
+3
0010
+4
-
+5
-
IMPORTANT
You cannot use the Unit Stand-alone Test Measurement Execution command for the following Camera Image Input
processing units.
• Camera Image Input, Camera Image Input GigE, Camera Image Input FH,
• Camera Image Input HDR, and Camera Image Input HDR Lite
362
Command Control
Bit
12 to 15
8 to 11
4 to 7
0001
0000
0011
0000
0000
0001
Bit
12 to 15
8 to 11
4 to 7
0001
0000
0011
0000
0000
0001
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0001
0000
0100
0000
0000
0001
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Unit No.
0000
Vision System FH/FZ5 Series User's Manual