Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
B010
+3
0010
+4
-
+5
-
Restart
Restarts the Sensor Controller.
IMPORTANT
• When a restart command is executed, BUSY does not turn off even after the command execution bit turns off.
After a restart command is executed, perform a memory clear of BUSY on the PLC side.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
F010
+3
0010
Response (Sensor Controller to PLC)
There is no response because restarting is performed.
Acquiring Scene Number
Acquires the current scene No.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
1000
+3
0020
374
Command Control
Bit
12 to 15
8 to 11
4 to 7
1011
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
1111
0000
0001
0010
0000
0001
Bit
12 to 15
8 to 11
4 to 7
0001
0000
0000
0000
0000
0010
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0 to 3
0000
Command code
0000
Vision System FH/FZ5 Series User's Manual