Scene Data Copy
Copies the data for the scene with the number specified with command argument 1 to the scene with the number
specified with command argument 2. If there is already data at the copy destination, the copied data is written
over that data.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
7010
+3
0010
+4
-
+5
-
+6
-
+7
-
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
7010
+3
0010
+4
-
+5
-
Scene Data Deletion
Deletes the data for the scene whose number is specified with command argument 1.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
7020
+3
0010
+4
-
+5
-
368
Command Control
Bit
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0111
0000
0010
0000
0000
0001
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
Copy source scene No.
0000
0000
Copy destination scene No.
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Number of the scene to delete
0000