Omron FH series User Manual page 278

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Setting item
Input/Output setting
Input mode
Input form
Output IP
address
UDP
Input port
No.
Output
port No.
Input/Out-
TCP
put port
No.
TCP
Server
TCP
Client
Input/Out-
put port
No.
IMPORTANT
• If the operation mode is set to Multi-line Random-trigger Mode, set a different I/O port number for each line.
• Change the IP address and subnet mask for [Address setting] and [Address setting 2] as required so that each
designate a different network address. If the same network address is specified, communications may not be
performed correctly.
• Be sure to change the output IP address from its factory default value in accordance with your network
environment.
4
Click [Apply] to apply the settings.
Click [Close] to close the System Settings Dialog Box .
276
Non-procedure Communications
Set value
[Factory default]
[Normal]
This item cannot be changed.
[ASCII]
This item cannot be changed.
a.b.c.d
a: 0 to 255
b: 0 to 255
Input the output destination IP address.
c: 0 to 255
d: 1 to 254
[0.0.0.0]
Set the port No. to use for data input with the Sensor Control-
0 to 65535
ler.
[9600]
Set the same number as on the host side.
0 to 65535
Set the port No. to use for data output with the Sensor Control-
*1
[−1]
ler.
*1:
When using the same
Set the same number as on the host side.
port as the input port.
Sets the port number used input and output data connected
0 to 65535
with the Sensor Controller.
[9876]
Set the same number as on the host side.
a.b.c.d
a: 0 to 255
b: 0 to 255
Input the connection destination IP address.
c: 0 to 255
d: 0 to 255
[10.5.5.101]
0 to 65535
Set the port No. to use for data I/O with the Sensor Controller.
[9876]
Set the same number as on the host side.
Description
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)