Omron FH series User Manual page 368

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Scroll
The image display window whose number is specified is moved the specified distance in parallel. The setting
range for the movement distance is not restricted. Also, because the scale for movement is independent of the
display zoom ratio, the movement is not affected by change in the zoom ratio.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
5010
+3
0010
+4
-
+5
-
+6
-
+7
-
+8
-
+9
-
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
5010
+3
0010
+4
-
+5
-
Zoom
Zooms the image display window whose number is specified in or out to the specified zoom ratio. The zoom ratio
here is the ratio compared to the original image (100%).
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
5020
+3
0010
+4
-
+5
-
+6
-
+7
-
366
Command Control
Bit
12 to 15
8 to 11
4 to 7
0101
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0101
0000
0001
0000
0000
0001
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0101
0000
0010
0000
0000
0001
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
Display image window number
0000
0000
X movement distance (camera coordinate
system)
0000
0000
Y movement distance (camera coordinate
system)
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Display image window number
0000
0000
Sets magnification. (Value multiplied by 1000)
Example)
25%: Enter 250 (0.25
0000
1,600%: Enter 16000 (16
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Description
Description
Description
×
1,000)
×
1,000)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents