Output When Multiple Items Are Set
The items that are set for output data numbers 0 through 7 are output to the PLC reception buffer in ascending order,
one data item at a time (16-bit units). Each time a data item is output, the GATE signal turns ON.
When this occurs, the first data item that was output to the PLC reception buffer (data 0) is overwritten by the next
output data item (data 1).
Therefore, the data output to the PLC reception buffer must be saved to PLC memory each time the GATE signal
turns ON for each data item.
Parallel data output
0: Measurement data 0
7. Measurement data 7
*1:
The operation of the DSA signal depends on whether handshaking for output control is enabled.
Reference:
Output Format (Parallel Data Output)
1
Click the [Parallel Data Output] icon (
2
In the Item Tab Area, click [Output format].
3
Select the output format in the output settings.
Setting value
[Factory default]
[Binary]
BCD
314
Parallel Communications
DO0 to
Measurement
DO15
signals
ON
GATE
signal
OFF
Data Output Control with Handshaking (p.32)
Data is output as 2's complement binary data.
Information on 2's Complement
Refer to
Definitions of Basic Terms in the Vision System FH/FZ5 Series User's Man-
ual (Cat. No. Z365).
Data is output expressing 1 digit with 4 bits and expressing a 3-digit integer and sign
with 16 bits.
• Bits 12 to 15
These bits give the sign. (positive: 0000, negative: 1111)
• Bits 0 to 11
Every 4 bits express 1 digit from ones place (bits 0 to 3: 1st digit) to the hundreds
place (bits 8 to 11: 3rd digit).
Data output order
16 bit
Measurement
data 0
data 7
) in the measurement unit list (flow).
Description
Vision System FH/FZ5 Series User's Manual
*1
PLC
Reception
buffer
for Communications Settings (Z342)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents