Omron FH series User Manual page 406

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
9000
+3
0030
+4
-
+5
-
Operation Log State Setting
Sets the logged operation state. This command allows configuring the logging operation state in the same
manner as for the Start/End Logging Operation buttons on the Main screen.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
A000
+3
0030
+4
-
+5
-
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
A000
+3
0030
+4
-
+5
-
404
Command Control
Bit
12 to 15
8 to 11
4 to 7
1001
0000
0000
0000
0000
0011
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
1010
0000
0000
0000
0000
0011
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
1010
0000
0000
0000
0000
0011
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Logging operation state
0: OFF
0000
1: ON
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Description
Description
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents