Omron FH series User Manual page 106

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Event name
Camera Connection Error
Meaning
The Camera connection is wrong.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
A Camera is not connected to the Con-
troller.
The Camera cable is broken.
Cause and
correction
The Camera Selection settings are not
correct in the Camera Image Input and
Camera Switching processing items.
A Camera is not connected to the
Camera port on the Controller accord-
ing to the Camera Selection settings in
the Camera Image Input and Camera
Switching processing items.
Attached
None
information
Precautions/
None
Remarks
Event name
System Error
Meaning
An error occurred in the system.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
Cause and
A serious error occurred in the system
correction
in the Controller.
Attached
None
information
Precautions/
None
Remarks
104
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Turn OFF the power supply, correctly
connect a Camera to the Controller,
and turn the power supply back ON.
Turn OFF the power supply, replace
the Camera cable with a new one, and
turn the power supply back ON.
Make suitable settings according to
the connected Cameras.
Turn OFF the power supply, connect a
Camera to the suitable Camera port,
and turn the power supply back ON.
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Consult your OMRON representative. Consult your OMRON representative.
Event code
3859 0000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
The Camera image will not be input, so measurements will
be performed on invalid images. This may result in the out-
put of unintentional measurement results.
EtherCAT LINK/ACT
---
Name
---
Prevention
Correctly connect a Camera to the
Controller and tighten the screws.
Use a flexible cable or take other mea-
sures to prevent the Camera cable
from becoming broken.
Make suitable settings according to
the connected Cameras.
Connect a Camera to the suitable
Camera port.
Event code
4802 0000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
All slave functionality stops, and measurement trigger sig-
nals and commands are not acknowledged.
EtherCAT LINK/ACT
---
Name
---
Prevention
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Always at startup
System
---
---
Always at startup
System
---
---

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents