Registering the Items To Output
In an expression, set the target for judgement (i.e., the measured value of a processing item or the
calculation result of an expression).
Up to 16 expressions from 0 to 15 can be set in each unit.
1
Click the [Parallel Judgement Output] icon (
2
In the Item Tab Area, click [Setting].
3
Set the items in the output settings area.
The selected output data number is displayed under the list.
4
Click the [...] button next to the expression box and set the expression.
Specify the processing items, measurement results, and measurement data in the expression.
You can also perform arithmetic or function calculations on the measurement data before it is output.
For calculation settings, refer to section of Calculation in FH/FZ5 Processing Item Function Reference
Manual (Cat. No. Z341).
5
Click the [...] button for the judgement condition, and then set the upper and lower limits to
judge as OK.
If the result data set in step 4 above is within the range set here, the result will be judged as OK.
6
Click the [...] button for the [Comment] box and enter an explanation of the expression.
7
Repeat steps 4 and 5 to set expressions for all of the required output data numbers.
316
Parallel Communications
) in the measurement unit list (flow).
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)