• Communicating with an OMRON PLC
(When [PLC Link (Sysmac CS/CJ/CP/One)] is selected for the Communications Module)
Setting item
Command area
Area
Address
Response area
Area
Address
Data output area
Area
Address
Output control
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Set value
[Factory default]
• [CIO Area (CIO)]
• Work Area (WR)
Set the Command Area.
• Holding Bit Area (HR)
The range of the EM Area depends on the model of the CPU
• Auxiliary Bit Area (AR)
Unit of the connected PLC.
• DM Area (DM)
• EM Area (EM0 to EMC)
0 to 99999
Set the first word address in the Command Area.
[0]
• [CIO Area (CIO)]
• Work Area (WR)
Set the Response Area.
• Holding Bit Area (HR)
The range of the EM Area depends on the model of the CPU
• Auxiliary Bit Area (AR)
Unit of the connected PLC.
• DM Area (DM)
• EM Area (EM0 to EMC)
0 to 99999
Set the first word address in the Response Area.
[100]
• [CIO Area (CIO)]
• Work Area (WR)
Set the Data Output Area.
• Holding Bit Area (HR)
The range of the EM Area depends on the model of the CPU
• Auxiliary Bit Area (AR)
Unit of the connected PLC.
• DM Area (DM)
• EM Area (EM0 to EMC)
0 to 99999
Set the first word address in the Data Output Area.
[200]
Set whether to provide an interlock with the PLC when per-
forming data output.
• None
None:
• [Handshaking]
Handshaking: Data is output after confirming DSA from the
Description
Data is output regardless of the status of sig-
nals from the PLC. GATE is always OFF.
PLC.