Configuring synchronization with SIMATIC IT (Page 581)
14.10.10

Reset step

You can reset and then restart an aborted step object (entire recipe, unit recipe, recipe step /
transition) with the "Start" command.
14.10.11

Set breakpoint

During batch control, you can set breakpoints in the open control recipe for each control recipe
element. If execution of the recipe reaches a recipe element with a breakpoint, only the run
marker is set and the recipe element is neither occupied nor activated.
14.10.12

Remove breakpoint

Removes a set breakpoint in the open control recipe for a control recipe element. The control
recipe element must have been selected beforehand.
14.10.13

Comment on batch element

During batch control, you can enter comments for an individual batch element–during or after
batch execution–without having to hold the batch.
14.10.14

Comment on messages

Opens a dialog for the entry of comments on the existing messages of batch control (system
messages, process messages, error messages).
14.10.15

Sign

You can use this function in Batch control for a signature prompt in the "SIMATIC BATCH:
Sign" dialog box to enter a signature.
Additional information
Signing conditions and status changes (Page 378)
SIMATIC BATCH V8.2
Operating Manual, 02/2016, A5E35958174-AA
Context help references
14.10 Shortcut menu commands