Default settings (IP PRECEDENCE, Priority=6, Low Delay=OFF, Throughput=OFF, Reliability=OFF,
Note:
Min Cost=OFF) is applied when the check box is not clicked.
Execute the following to make the changed data effective after assigning ToS data for signaling packet.
Note:
- Internal PHE module initialization by ADPM command or system initialization
- IPPAD card initialization (MB key ON/OFF operation or make-busy cancel by MBPM command)
- Re-registration of IP terminals
Change the default port number (= 64000) if required.
STEP 4
Open ADTM command and specify the port number.
Be sure to initialize the Internal PHI-PRI module by using ADPM command when the port number is
Note:
changed.
Specify Route Class Data
STEP 5
Open ARTD command and specify route class data on Virtual Speech Channel and Virtual Signaling Chan-
nel. The following is an example when the Virtual Signaling Channel=10 and the Virtual Speech Channel
=20:
RT=10 (Virtual Signaling Channel)
RT=20 (Virtual Speech Channel)
CDN60:TC/EC=1 (EC) (Virtual Speech Channel)
EC is applied only for Virtual Speech Channel.
Note:
To change the data for existing route (RT), initialize or reboot the trunk device such as circuit card, MG-
Note:
PRI/PRA, or VS-32.
Specify Application Data for Trunk
STEP 6
Open ARTI command and specify application data for trunk on Virtual Speech Channel and Virtual Sig-
naling Channel as follows:
RT=10
RT=20
CDN68 VIR=2 (indicates connecting to MG-PRI/PRA)
To change the data for existing route (RT), initialize or reboot the trunk device such as circuit card, MG-
Note:
PRI/PRA, or VS-32.
To use FAX, specify the FAX relay settings in the following:
CDN71 (FXD)
CDN72 (FXJS)
CDN73 (FXPT)
CDN74 (FXPS): This parameter appears when 1 (G.711) or 2 (G.726) is selected in FXPT.
Specify Trunk Data (Bch)
STEP 7
VOL.2-953