Check the system message of the Telephony Server.
Check the MG(BRI) is physically connected to ISDN network.
Also confirm the line cable between;
- MDF and MG(BRI)
- MDF and DSU
Check the data assignment of the Telephony Server side and MG(BRI) side.
Telephony Server: Is the data assignment on each PCPro command correct?
MG(BRI): Check the configuration data assigned from the maintenance console.
[Lights green]
Go on to STEP 5.
STEP 5: Speech test through MG(BRI). Call origination/termination OK?
[Call origination/termination does not operate normally]
Check the system message of the Telephony Server.
Check the MG(BRI) is physically connected to ISDN network.
Also confirm the line cable between:
- MDF and MG(BRI)
- MDF and DSU
Check that the cable is not damaged. (Test the continuity in the LAN cable.)
Check the data assignment of the Telephony Server side and MG(BRI) side.
Telephony server: Is the data assignment on each PCPro command correct?
MG(BRI): Check the configuration data assigned from the maintenance console.
Check the contract status of the ISDN line.
[B lamp of LINE0/1 does not light]
Indicates that all channels are in idle state, check the office data assignment.
[B lamp of LINE0/1 flashes]
Flashes slow: Either of the channels is set to make-busy, and the other is in idle state. Check the
office data assignment.
Flashes fast: B1 and B2 channels are both in make-busy state. Check the office data assignment.
VOL.2-837
MG(BRI) [SCA-2BRIA/MG-2BRIA]