13.3.3 Procedure Overview
This section explains how to set up MG-PRI/PRA. The set-up have to be performed by specifying data of the
Telephony Server and MG-PRI/PRA. The following describes the basic step overview.
"DRS (Device Registration Server)" used in this section refers to the Telephony Server. The Telephony
Note:
Server acts as DRS for MG-PRI/PRA using Proprietary Protocol.
<MG-PRI/PRA Settings>
IP Addresses of DRS and Default Gateway
STEP 1
<Telephony Server Settings via PCPro>
Specify System Data by ASYD
STEP 1
Specify System Data by ASYDL
STEP 2
Specify Location ID Data by ALOCL
STEP 3
Specify Internal PHI-PRI module by ADPM
STEP 4
Specify Route Data by ARTD
STEP 5
Specify Application Data by ARTI
STEP 6
Specify Trunk Data (Bch) by ATRK
STEP 7
Specify Destination Node by ADPC
STEP 8
Specify CSC information by ACSC
STEP 9
Specify CIC information by ACIC1
STEP 10
Specify Trunk Data (Dch) by ATRK
STEP 11
Unblock Virtual Speech Channel by MBTK
STEP 12
Specify MG-PRI/PRA information by AMGIL
STEP 13
Specify MG-PRI/PRA Voice Control Data by AMGVL
STEP 14
- When using Least Cost Routing for MG-PRI/PRA, the following optional data is required:
Specify the applied object type to be modified tenant data (Option)
STEP 15
Specify MA-ID and the area information (Option)
STEP 16
Add MA-ID to terminals (Option)
STEP 17
Specify a required minimum of the digits of MA-ID Access Code (Option)
STEP 18
Specify the MA-ID access code (Option)
STEP 19
Note 1
Note 1
Note 1
VOL.2-948
MG-PRI/PRA
Note 1
Note 1

Hide quick links: