NEC Univerge sv8500 Manual page 1250

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

Δ
18. SHOW
TCS_E1_1
This command is used to display E1 Dch settings for trunk.
MG-PRI > SHOW TCS_E1_1
value is 0x9080
Dch Control
Dch Mode
Dch Signal Logic
Dch-1 Drop/Insert
Dch-2 Drop/Insert
Drop/Insert Mode
Data Transfer Speed
Drop/Insert Time Slot
Dch Signaling Set
19. SHOW
Δ
TCS_E1_2
This command is used to display E1 settings for trunk.
MG-PRI > SHOW TCS_E1_2
value is 0x1000
Multi-frame Remote Alarm
Alarm Release Timing
Line Signal
CRC4
DTI Mode
CRC Multi-frame Format
Ebit Automatic Sending
TS16 Control
Dch Mode
Loop Back Pattern
Alarm Detect/Release Type :0
The current setting is displayed.
- Dch Control (0/1=Disable/Enable)
- Dch Mode (0/1=User/Network)
:1
- Dch Signal Logic (0/1=Positive Logic/Negative Logic)
:0
- Dch 1 (0/1=Disable/Enable)
:0
- Dch 2 (0: Fixed)
:1
- Mode (0/1=Fixed value/Set value)
:0
:0
- Data Transfer Speed (0=64K/1=56K/2=48K)
:0
- Time Slot Number (1-31)
:16
- Dch Signaling Set (0: Fixed)
:0
The current setting is displayed.
- Multi-frame Remote Alarm (0/1=Enable/Disable)
- Alarm Release Timing (0/1=Short/Long)
:0
- Line Signal (0/1=HDB3/AMI)
:0
- CRC4 (0/1=Disable/Enable)
:0
- DTI Mode (0: Fixed)
:1
:0
- CRC Multi-frame Format (0/1=Disable/Enable)
:0
- Ebit Automatic Sending (0/1=Disable/Enable)
:0
- TS16 Control (0/1=Data Through/Signaling
:0
- Dch Mode (0/1=ITU-T/AT&T)
:0
- Loop Back Pattern (0: Fixed)
:0
- Alarm Detect/Release Type (0/1=ETSI/ITU-T)
VOL.2-997
MG-PRI/PRA

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents