NEC Univerge sv8500 Manual page 1167

Fp85-110 s7
Hide thumbs Also See for Univerge sv8500:
Table of Contents

Advertisement

7.
SET FAX_DETECTION_TIME
Assign the effective switching timer for FAX
MG-BRI(SIP)> SET FAX_DETECTION_TIME P1
FAX Enable Timer setting succeeded.
In order to make a setup reflect. re-starting is
required after saving a configuration data
by SAVE command.
Execute the "SAVE" command before finishing the maintenance command to reflect change.
Note:
8.
SET HC_RCV_TIMER
Assign the Time-out value for Telephony Server health check waiting process.
MG-BRI(SIP)> SET HC_RCV_TIMER P1
Health-Check Receive Timer setting succeeded.
In order to make a setup reflect. re-starting is
required after saving a configuration data
by SAVE command.
Execute the "SAVE" command before finishing the maintenance command to reflect change.
Note:
9.
SET INTERFACE
Assign the speed and activation mode of Ether controller.
MG-BRI(SIP)> SET INTERFACE
SPEED [1(AUTO)/2(100M)/3(10M)]: 3
DUPLEX [F(FULL)/H(HALF)]: F
Ethernet Speed setting succeeded.
In order to make a setup reflect. re-starting is
required after saving a configuration data
by SAVE command.
DUPLEX setting will not be effective when "AUTO" was chosen for speed.
Note:
Assign the proper speed adjusting the network devices (router, HUB) on the destination.
Note:
VOL.2-914
MG(BRI) [SCA-2BRIA/MG-2BRIA]
P1: Assignment of effective time
0: No switching to FAX
1-5: Effective switching timer (minute)
(Default: 1 minute)
6-9: Switching always effective
The result is shown.
P1: Specify Time (Second) (30 sec-
ond interval)
Effective range: 120-300 in 30-sec-
ond step (default: 150 seconds)
The result is shown.
AUTO: AUTO Negotiation (default)
100M: 100Mbps Fixed mode
10M: 10Mbps Fixed mode
FULL: Full-duplex mode
HALF: Half-duplex mode
The result is shown.