Mitel 6867i Administrator's Manual page 389

6800 series
Hide thumbs Also See for 6867i:
Table of Contents

Advertisement

Ring Tone Pattern (Sylantro Servers)
CALL CRITERIA
alert-acd (auto call distribution)
alert-community-1
alert-community-2
alert-community-3
alert-community-4
alert-emergency
alert-external
alert-group
alert-internal
alert-priority
A System Administrator can configure the ring tone cadences if required, using the configuration
files. The following table identifies the different Bellcore ring tone patterns and cadences.
BELLCORE
PATTERN
TONE
ID
(Standard)
1
Bellcore-dr2
2
Bellcore-dr3
3
Bellcore-dr4
4
Bellcore-dr5
5
BELLCORE TONES FOR EACH CALL CRITERIA
Normal ringing (default)
Bellcore-dr2
Bellcore-dr3
Bellcore-dr4
Bellcore-dr5
Silent
PATTERN
CADENCE
Ringing
2s On
Silent
4s Off
Ringing
Long
Silent
Ringing
Long
Silent
Long
Ringing
Short
Silent
Ringing
Short
Silent
Ringing
Long
Silent
Ringing
Short
Silent
Ringing
Long
Silent
Ringing
Short
Silent
Ringing
Operational Features
MINIMUM
NOMINAL
DURATION
DURATION
(MS)
(MS)
1800
2000
3600
4000
630
800
315
400
630
800
3475
4000
315
400
145
200
315
400
145
200
630
800
2975
4000
200
300
145
200
800
1000
145
200
200
300
2975
4000
450
500
MAXIMUM
DURATION
(MS)
2200
4400
1025
525
1025
4400
525
525
525
525
1025
4400
525
525
1100
525
525
4400
550
5-128