xStack DES-6500 Modular Layer 3 Chassis Ethernet Switch CLI Manual
config system_severity
Parameters
Restrictions
Example usage:
To configure the system severity:
to the SNMP agent (trap), the Switch's log or both. Events occurring
on the Switch are separated into three main categories.
Information – Events classified as information are basic events
occurring on the Switch that are not deemed as problematic,
such as enabling or disabling various functions on the Switch.
Warning - Events classified as warning are problematic events
that are not critical to the overall function of the Switch but do
require attention, such as unsuccessful downloads or uploads
and failed logins.
Critical – Events classified as critical are fatal exceptions
occurring on the Switch, such as hardware failures or spoofing
attacks.
Choose one of the following to identify where severity messages are
to be sent.
trap – Entering this parameter will define which events
occurring on the Switch will be sent to a SNMP agent for
analysis.
log – Entering this parameter will define which events
occurring on the Switch will be sent to the Switch's log for
analysis.
all – Entering this parameter will define which events occurring
on the Switch will be sent to a SNMP agent and the Switch's
log for analysis.
Choose one of the following to identify what type of severity
warnings are to be sent to the destination entered above.
critical – Entering this parameter along with the proper
destination, stated above, will instruct the Switch to send only
critical events to the Switch's log or SNMP agent.
warning – Entering this parameter along with the proper
destination, stated above, will instruct the Switch to send
critical and warning events to the Switch's log or SNMP agent.
information – Entering this parameter along with the proper
destination, stated above, will instruct the switch to send
informational, warning and critical events to the Switch's log or
SNMP agent.
Only Administrator-level users can issue this command.
DES-6500:4#config system_severity trap
critical
Command: config system_severity trap
critical
Success.