xStack DES-6500 Modular Layer 3 Chassis Ethernet Switch CLI Manual
config authen parameter response_timeout
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure the response timeout for 60 seconds:
D E S - 6 5 0 0 : 4 # c o n f i g a u t h e n p a r a m e t e r r e s p o n s e _ t i m e o u t
6 0
C o m m a n d : c o n f i g a u t h e n p a r a m e t e r r e s p o n s e _ t i m e o u t 6 0
S u c c e s s .
D E S - 6 5 0 0 : 4 #
Example usage:
To configure the response timeout to never time out:
D E S - 6 5 0 0 : 4 # c o n f i g a u t h e n p a r a m e t e r r e s p o n s e _ t i m e o u t
0
C o m m a n d : c o n f i g a u t h e n p a r a m e t e r r e s p o n s e _ t i m e o u t 0
S u c c e s s .
D E S - 6 5 0 0 : 4 #
config authen parameter attempt
Purpose
Syntax
Description
Used to configure the amount of time the Switch will wait for a user
to enter authentication before timing out.
config authen parameter response_timeout <int 0-255>
This command will set the time the Switch will wait for a response of
authentication from the user.
response_timeout <int 0-255> - Set the time, in seconds, the Switch
will wait for a response of authentication from the user attempting to
log in from the command line interface or telnet interface. An entry of
0 will denote that the Switch will never time out while waiting for a
response of authentication. The default setting is 30 seconds.
Only Administrator-level users can issue this command.
Used to configure the maximum number of times the Switch will
accept authentication attempts.
config authen parameter attempt <int 1-255>
This command will configure the maximum number of times the
Switch will accept authentication attempts. Users failing to be
authenticated after the set amount of attempts will be denied
access to the Switch and will be locked out of further authentication
attempts. Command line interface users will have to wait 60
seconds before another authentication attempt. Telnet users will be