Analog In/Out - Danfoss VLT HVAC Basic Drive FC 101 Programming Manual

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Parameter Lists

5.1.8 6-** Analog In/Out

Par.
Parameter description
No. #
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-02
Fire Mode Live Zero Timeout Function
6-1* Analog Input 53
6-10
Terminal 53 Low Voltage
5
5
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-19
Terminal 53 mode
6-2* Analog Input 54
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-29
Terminal 54 mode
6-7* Analog/Digital Output 45
6-70
Terminal 45 Mode
6-71
Terminal 45 Analog Output
6-72
Terminal 45 Digital Output
6-73
Terminal 45 Output Min Scale
6-74
Terminal 45 Output Max Scale
6-76
Terminal 45 Output Bus Control
6-9* Analog/Digital Output 42
6-90
Terminal 42 Mode
6-91
Terminal 42 Analog Output
6-92
Terminal 42 Digital Output
6-93
Terminal 42 Output Min Scale
6-94
Terminal 42 Output Max Scale
6-96
Terminal 42 Output Bus Control
110
®
VLT
HVAC Basic Drive FC 101
Default value
10 s
[0] Off
[0] Off
0.07 V
10 V
4 mA
20 mA
0 N/A
ExpressionLimit
0.01 s
[1] Voltage mode
0.07 V
10 V
4 mA
20 mA
0 N/A
ExpressionLimit
0.01 s
[1] Voltage mode
[0] 0-20 mA
[0] No operation
[0] No operation
0%
100%
0 N/A
[0] 0-20 mA
[0] No operation
[0] No operation
0%
100%
0 N/A
Danfoss A/S © 04/2018 All rights reserved.
2-set-up
Change
Conversion
during
operation
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
index
0
Uint8
Uint8
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
Uint8
Uint8
Uint8
Uint8
-2
Uint16
-2
Uint16
0
Uint16
Uint8
Uint8
Uint8
-2
Uint16
-2
Uint16
0
Uint16
MG18B502