Introduction

1 Introduction

1.1 Purpose of the Manual

This programming guide provides information for advance-
Menusd programming of the frequency converter. It
provides a complete overview of all parameters and
descriptions for all parameters.
The programming guide is intended for use by qualified
personnel.
To operate the frequency converter safely and profes-
sionally, read and follow the programming guide, and pay
particular attention to the safety instructions and general
warnings.

1.2 Document and Software Version

This manual is regularly reviewed and updated. All
suggestions for improvement are welcome.
Edition
Remarks
MG18B5xx
Update to new
software version.
Table 1.1 Document and Software Version
From software version 4.0x and later (production week 33
2017 and after), the variable speed heat sink cooling fan
function is implemented in the frequency converter for
power sizes 22 kW (30 hp) 400 V IP20 and below, and 18.5
kW (25 hp) 400 V IP54 and below. This function requires
software and hardware updates and introduces restrictions
with regards to backwards compatibility for H1–H5 and I2–
I4 enclosure sizes. Refer to Table 1.2 for the limitations.
MG18B502
Programming Guide
compatibility
Old software
(OSS-file version 3.xx
and below)
New software
(OSS-file version 4.xx
or higher)
Hardware
compatibility
Old power card
(production week 33
2017 or before)
New power card
(production week 34
2017 or after)
Software version
4.2x
Table 1.2 Software and Hardware Compatibility

1.3 Safety Symbols

The following symbols are used in this guide:
WARNING
Indicates a potentially hazardous situation that could
result in death or serious injury.
CAUTION
Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.
NOTICE
Indicates important information, including situations that
can result in damage to equipment or property.
Danfoss A/S © 04/2018 All rights reserved.
Old control card
Software
(production week
33 2017 or before)
Yes
No
Old control card
(production week
33 2017 or before)
Yes (only software
version 3.xx or
below)
Yes (MUST update
software to version
3.xx or below, the
fan continuously
runs at full speed)
1
New control card
(production week
34 2017 or after)
No
Yes
New control card
(production week
34 2017 or after)
Yes (MUST update
software to version
4.xx or higher)
Yes (only software
version 4.xx or
higher)
3
1