Parameter Lists
5.1.8 6-** Analog In/Out
Par. No. #
6-0* Analog I/O Mode
6-00
6-01
6-1* Analog Input 53
6-10
6-11
5
5
6-12
6-13
6-14
6-15
6-16
6-19
6-2* Analog Input 54
6-20
6-21
6-22
6-23
6-24
6-25
6-26
6-29
6-7* Analog/Digital Output 45
6-70
6-71
6-72
6-73
6-74
6-76
6-9* Analog/Digital Output 42
6-90
6-91
6-92
6-93
6-94
6-96
6-98
92
Parameter description
Live Zero Timeout Time
Live Zero Timeout Function
Terminal 53 Low Voltage
Terminal 53 High Voltage
Terminal 53 Low Current
Terminal 53 High Current
Terminal 53 Low Ref./Feedb. Value
Terminal 53 High Ref./Feedb. Value
Terminal 53 Filter Time Constant
Terminal 53 mode
Terminal 54 Low Voltage
Terminal 54 High Voltage
Terminal 54 Low Current
Terminal 54 High Current
Terminal 54 Low Ref./Feedb. Value
Terminal 54 High Ref./Feedb. Value
Terminal 54 Filter Time Constant
Terminal 54 mode
Terminal 45 Mode
Terminal 45 Analog Output
Terminal 45 Digital Output
Terminal 45 Output Min Scale
Terminal 45 Output Max Scale
Terminal 45 Output Bus Control
Terminal 42 Mode
Terminal 42 Analog Output
Terminal 42 Digital Output
Terminal 42 Output Min Scale
Terminal 42 Output Max Scale
Terminal 42 Output Bus Control
Drive Type
®
VLT
HVAC Basic Drive FC 101 Programming Guide
Default value
10 s
[0] Off
0.07 V
10 V
4 mA
20 mA
0 N/A
ExpressionLimit
0.01 s
[1] Voltage mode
0.07 V
10 V
4 mA
20 mA
0 N/A
ExpressionLimit
0.01 s
[1] Voltage mode
[0] 0-20 mA
[0] No operation
[0] No operation
0 %
100 %
0 N/A
[0] 0-20 mA
[0] No operation
[0] No operation
0 %
100 %
0 N/A
0 N/A
MG18B302 - Rev. 2013-09-02
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
Type
0
Uint8
-
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-2
Uint16
-2
Uint16
-5
Uint16
-5
Uint16
-3
Int32
-3
Int32
-2
Uint16
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint16
-
Uint8
-
Uint8
-
Uint8
-2
Uint16
-2
Uint16
0
Uint16
0
Uint8