1.3.5 Fuses and Circuit Breakers

Branch circuit protection
In order to protect the installation against electrical and fire hazard, all branch circuits in an installation, switch gear,
machines, etc., must be protected from short-circuits and overcurrents according to national and local regulations.
Short circuit protection
Danfoss
Overcurrent protection
Provide overload protection to avoid overheating of the cables in the installation. Overcurrent protection must always be
carried out according to local and national regulations. Circuit breakers and fuses must be designed for protection in a
circuit capable of supplying a maximum of 100,000 A
UL/Non-UL compliance
Use the circuit breakers or fuses listed in Table 1.17 to ensure compliance with UL or IEC 61800-5-1.
Circuit breakers must be designed for protection in a circuit capable of supplying a maximum of 10,000 Arms (symmetrical),
480 V maximum.
In the event of malfunction, failure to follow the protection recommendation may result in damage to the adjustable
frequency drive.
Power [kW]
3x200–240 V IP20
0.25
0.37
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
3x380–480 V IP20
0.37
0.75
1.5
2.2
3
4
5.5
7.5
11
15
18.5
22
16
Quick Guide
Circuit Breaker
UL
Non-UL
Cutler-Hammer
Moeller NZMB1-
EGE3100FFG
A125
Cutler-Hammer
Moeller NZMB1-
JGE3150FFG
A160
Cutler-Hammer
Moeller NZMB1-
JGE3200FFG
A200
Danfoss A/S © Rev. 2014-01-22 All rights reserved.
(symmetrical), 480 V maximum.
rms
Bussmann
Bussmann
Type RK5
Type RK1
FRS-R-10
KTN-R10
FRS-R-10
KTN-R10
FRS-R-10
KTN-R10
FRS-R-10
KTN-R10
FRS-R-15
KTN-R15
FRS-R-25
KTN-R25
FRS-R-50
KTN-R50
FRS-R-50
KTN-R50
FRS-R-80
KTN-R80
FRS-R-100
KTN-R100
FRS-R-100
KTN-R100
FRS-R-150
KTN-R150
FRS-R-150
KTN-R150
FRS-R-200
KTN-R200
FRS-R-200
KTN-R200
FRS-R-10
KTS-R10
FRS-R-10
KTS-R10
FRS-R-10
KTS-R10
FRS-R-15
KTS-R15
FRS-R-15
KTS-R15
FRS-R-15
KTS-R15
FRS-R-25
KTS-R25
FRS-R-25
KTS-R25
FRS-R-50
KTS-R50
FRS-R-50
KTS-R50
FRS-R-80
KTS-R80
FRS-R-80
KTS-R80
Fuse
UL
Bussmann
Bussmann
Type J
Type T
JKS-10
JJN-10
JKS-10
JJN-10
JKS-10
JJN-10
JKS-10
JJN-10
JKS-15
JJN-15
JKS-25
JJN-25
JKS-50
JJN-50
JKS-50
JJN-50
JKS-80
JJN-80
JKS-100
JJN-100
JKS-100
JJN-100
JKS-150
JJN-150
JKS-150
JJN-150
JKS-200
JJN-200
JKS-200
JJN-200
JKS-10
JJS-10
JKS-10
JJS-10
JKS-10
JJS-10
JKS-15
JJS-15
JKS-15
JJS-15
JKS-15
JJS-15
JKS-25
JJS-25
JKS-25
JJS-25
JKS-50
JJS-50
JKS-50
JJS-50
JKS-80
JJS-80
JKS-80
JJS-80
Non-UL
Max fuse
Type G
10
10
10
10
16
25
50
50
65
125
125
160
160
200
200
10
10
10
16
16
16
25
25
50
50
65
65