Data Readouts - Danfoss VLT HVAC Basic Drive FC 101 Programming Manual

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Parameter Lists

5.1.13 16-** Data Readouts

Par. No. #
Parameter description
16-0* General Status
16-00
Control word
16-01
Reference [unit]
16-02
Reference [%]
16-03
Status word
16-05
Main actual value [%]
5
5
16-09
Custom readout
16-1* Motor Status
16-10
Power [kW]
16-11
Power [hp]
16-12
Motor voltage
16-13
Frequency
16-14
Motor current
16-15
Frequency [%]
16-16
Torque [Nm]
16-17
Speed [RPM]
16-18
Motor thermal
16-22
Torque [%]
16-3* Drive Status
16-30
DC link voltage
16-34
Heatsink temperature
16-35
Inverter thermal
16-36
Inverter nominal current
16-37
Inverter maximum current
16-38
SL controller state
16-5* Ref. & Feedb.
16-50
External reference
16-52
Feedback[Unit]
16-54
Feedback 1 [Unit]
16-55
Feedback 2 [Unit]
16-6* Inputs & Outputs
16-60
Digital input
16-61
Terminal 53 setting
16-62
Analog input AI53
16-63
Terminal 54 setting
16-64
Analog input AI54
16-65
Analog output AO42 [mA]
16-66
Digital output
16-67
Pulse input #29 [Hz]
16-71
Relay output [bin]
16-72
Counter A
16-73
Counter B
16-79
Analog output AO45
16-8* Fieldbus & FC Port
16-86
FC port REF 1
16-9* Diagnosis Readouts
16-90
Alarm word
16-91
Alarm word 2
114
®
VLT
HVAC Basic Drive FC 101
Default value
0 N/A
0
0%
0 N/A
0%
0 CustomReadoutUnit
0 kW
0 hp
0 V
0 Hz
0 A
0%
0 Nm
0 RPM
0%
0%
0 V
0 °C
0%
0 A
0 A
0 N/A
0%
0
0
0
0 N/A
[0] Current mode
1 N/A
[0] Current mode
1 N/A
0 mA
0 N/A
0 N/A
0 N/A
0 N/A
0 N/A
0 mA
0 N/A
0 N/A
0 N/A
Danfoss A/S © 04/2018 All rights reserved.
2-set-up
Change
Conversion
during
operation
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
All set-ups
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
FALSE
Type
index
0
Uint16
-3
Int32
-1
Int16
0
Uint16
-2
Int16
-2
Int32
-3
Uint32
-3
Uint32
-1
Uint32
-1
Uint32
-2
Uint16
-1
Uint16
0
Int32
0
Int32
0
Uint8
0
Int16
0
Uint32
100
Int8
0
Uint8
-2
Uint16
-2
Uint16
0
Uint8
-1
Int16
-3
Int32
-3
Int32
-3
Int32
0
Uint16
Uint8
-2
Uint16
Uint8
-2
Uint16
-2
Uint16
0
VisStr[4]
0
Int32
0
Uint16
0
Int16
0
Int16
-2
Uint16
0
Int16
0
Uint32
0
Uint32
MG18B502