Operation/Display; Load And Motor - Danfoss VLT HVAC Basic Drive FC 101 Programming Manual

Hide thumbs Also See for VLT HVAC Basic Drive FC 101:
Table of Contents

Advertisement

Parameter Lists

5.1.2 0-** Operation/Display

Par. No. # Parameter description
0-0* Basic Settings
0-01
Language
0-03
Regional Settings
0-04
Operating State at Power-up
0-06
GridType
0-07
Auto DC Braking
5
5
0-1* Set-up Operations
0-10
Active Set-up
0-11
Programming Set-up
0-12
Link Setups
0-3* LCP Custom Readout
0-30
Custom Readout Unit
0-31
Custom Readout Min Value
0-32
Custom Readout Max Value
0-37
Display Text 1
0-38
Display Text 2
0-39
Display Text 3
0-4* LCP Keypad
0-40
[Hand on] Key on LCP
0-42
[Auto on] Key on LCP
0-44
[Off/Reset] Key on LCP
0-5* Copy/Save
0-50
LCP Copy
0-51
Set-up Copy
0-6* Password
0-60
Main Menu Password

5.1.3 1-** Load and Motor

Par. No. # Parameter description
1-0* General Settings
1-00
Configuration Mode
1-01
Motor Control Principle
1-03
Torque Characteristics
1-06
Clockwise Direction
1-1* Motor Selection
1-10
Motor Construction
1-14
Damping Gain
1-15
Low Speed Filter Time Const
1-16
High Speed Filter Time Const
1-17
Voltage filter time const
1-2* Motor Data
1-20
Motor Power
1-22
Motor Voltage
1-23
Motor Frequency
1-24
Motor Current
1-25
Motor Nominal Speed
88
®
VLT
HVAC Basic Drive FC 101 Programming Guide
Default value
[0] English
ExpressionLimit
[0] Resume
ExpressionLimit
[1] On
[1] Set-up 1
[9] Active Set-up
[20] Linked
[1] %
0 CustomReadoutUnit
100 CustomReadoutUnit
[]
[]
[]
[1] Enabled
[1] Enabled
[1] Enabled
[0] No copy
[0] No copy
0 N/A
Default value
[0] Open Loop
[1] VVC+
[1] Variable Torque
[0] Normal
[0] Asynchron
120 %
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
ExpressionLimit
MG18B302 - Rev. 2013-09-02
2-set-up
Change
Conver-
during
sion index
operation
1 set-up
TRUE
1 set-up
FALSE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
FALSE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
FALSE
1 set-up
FALSE
1 set-up
TRUE
2-set-up
Change
Conver-
during
sion index
operation
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
1 set-up
FALSE
All set-ups
FALSE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
All set-ups
FALSE
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-2
Int32
-2
Int32
0
VisStr[21]
0
VisStr[26]
0
VisStr[26]
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Uint16
Type
-
Uint8
-
Uint8
-
Uint8
-
Uint8
-
Uint8
0
Int16
-2
Uint16
-2
Uint16
-3
Uint16
-
Uint8
0
Uint16
0
Uint16
-2
Uint32
67
Uint16