2) Remove the separation claw release component [1] and the tag [2] on
the fixing feeder assembly.
Remove foreign matter, such as an adhesive of tape on the feeder belt.
[2]
3) Remove the retaining tape of the tag [1] and open the fixing delivery
assembly [2].
[2]
4) Remove the two nip pressure release screws [2] connecting to the
cable of tag.
[2]
F-2-15
[1]
F-2-16
[1]
F-2-17
[1]
[1]
5) Close the fixing delivery assembly
2.2.5 Checking the Corona Assembly and the Dust-
proofing Glass
1) Detach the feeder assembly front cover (Right) [2] using the two
screws [1].
[1]
[2]
2) Remove the screw [1] and the fixture [2], and then remove the
connector [3].
[2]
[1]
Chapter 2