Chapter 5
for use in the machine (by changing the pin position; REAR).
[C]
[A]
2) Arrange the mirror positioning tool so that it is ready for use in the
machine (by changing the pin position; FRONT).
[A]
[B]
3) Fit the pins of the mirror positioning tool (front [2]; rear [3]) into the
appropriate holes of the No. 1/No. 2 mirror base).
5-42
[B]
[A]
[B]
F-5-155
[C]
[B]
[A]
F-5-156
4) Secure the end of the cable that has temporarily been fixed in place
on the hook of the reader unit frame.
5) Fully tighten the screws on the cable fixing plate both at the front and
the rear.
6) Detach the mirror positioning tool (FRONT, REAR).
7) Put the detached parts back on by reversing the foregoing steps.
[1]
F-5-157
[3]
[2]
F-5-158