Chapter 5
[1]
3) Shift the control panel [1] together with the cover; then, remove the
snap band [2], and disconnect the connector [3].
[2]

5.4.12.11 Removing the Scanner Drive Cable

1) Remove the 2 screws [1], and detach the reading glass retainer [2].
When detaching the reading glass retainer, be sure to take care so that
the leaf spring will not come off.
2) Remove the reading glass [3].
3) Remove the 3 screws [4], and detach the left glass retainer [5].
[3]
[2]
[1]
[4]
5-38
[2]
F-5-136
[1]
F-5-137
0008-7879
[4]
[5]
F-5-138
When mounting the reading glass retainer, be sure to hold down both
edges of the left spring [A] while fixing it in place. (Take care not to
bend the sponge.)
Be sure to mount it while butting the reading glass retainer [B] against
the reading glass [C].
Check to be sure that the side of the reading glass is in contact with the
leaf spring [D] of the reading glass retainer.
If not, dust can collect on the reading glass, causing lines in output
images.
[A]
F-5-139