Feeder; Feeder List - Canon iR6570 series Service Manual

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

Chapter 16
Sub-item
RG-MF
<CST-ADJ>
Sub-item
C3-STMTR
C3-A4R
C4-STMTR
C4-A4R
MF-A4R
MF-A6R
MF-A4
C3-LVOL
C3-HVOL
C4-LVOL
C4-HVOL
<MISC>
Sub-item
ATM

16.4.2 FEEDER

16.4.2.1 FEEDER List

Sub-item
DOCST
LA-SPEED
16-28
COPIER > ADJUST > FEED-ADJ
Description
Use it to adjust the registration for manual pickup.
adjustment range: -50 to 50
T-16-28
COPIER > ADJUST > CST-ADJ
Description
Use it to enter the paper width basic value for cassette 3 (STMTR).
adjustment range: 0 to 255
Use it to enter the paper width basic value for cassette 3 (A4R).
adjustment range: 0 to 255
Use it to enter the paper width basic value for cassette 4 (STMTR).
adjustment range: 0 to 255
Use it to enter the paper width basic value for cassette 4 (A4R).
adjustment range: 0 to 255
Use it to enter the paper width basic value for the manual feed tray (A4R).
adjustment range: 0 to 255
Use it to enter the paper width basic value for the manual feed tray (A6R).
adjustment range: 0 to 255
Use it to enter the paper width basic value for the manual feed tray (A4).
adjustment range: 0 to 255
Use it to enter the capacity of the cassette 3 (50 sheets).
adjustment range: 0 to 255
Use it to enter the capacity of the cassette 3 (275 sheets).
adjustment range: 0 to 255
Use it to enter the capacity of the cassette 4 (50 sheets).
adjustment range: 0 to 255
Use it to adjust the capacity of the cassette 4 (275 sheets).
adjustment range: 0 to 255
T-16-29
COPIER > ADJUST > MISC
Description
Use it to make settings related to the atmospheric pressure of the site of
installation.
settings range: 0 to 2 (default: 0)
0: 1 to 0.75 atm (up to elevation of 2500 m)
1: 0.75 to 0.70 atm (elevation between 2500 and 300 m)
2: 0.70 to 0.65 atm (elevation between 300 and 3500 m)
T-16-30
COPIER > FEEDER > ADJUST
Description
Use it to adjust the original image leading edge position.
- a higher setting will delay the timing for the image leading edge.
adjustment range: -50 to 50 (unit: 0.1 mm)
Use it to adjust the original feed speed in feeder stream reading mode.
- a higher setting will increase the speed (i.e., contracts the image).
adjustment range: -30 to 30 (unit: 0.1%)
Level
1
Level
1
1
1
1
1
1
1
1
1
1
1
Level
1
0009-6358
Level
1
1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: