Adjusting The Fixing Inlet Guide; Fixing Web Sensor; Removing The Fixing Web Sensor; Fixing Shutter Sensor - Canon iR6570 series Service Manual

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

Chapter 9
[1]
[2]
[3]
[5]
3) Detach the fixing inlet sensor [1] from the fixing inlet guide base.
[1]
Be sure to mount the fixing inlet guide base where it was in step 1).

9.5.16.2 Adjusting the Fixing Inlet Guide

- Adjust the position of the solenoid using the two screws [1] so that the
fixing inlet guide will be positioned as indicated when the solenoid
turns on.
Fixing roller
Pressure roller
<Points to Note When Making Adjustments in th Field>
- The inlet guide is in low position when the solenoid (SL1) goes on.
9-42
[1]
[2]
[4]
[3]
F-9-127
F-9-128
0009-4884
[1]
Inlet guide
Solenoid
F-9-129
- The height of the inlet guide must be such that the difference between
the front and the rear must be 0.2 mm or less.
- As necessary, adjust the height of the inlet guide by loosening the
fixing screw on the height adjusting support plate.

9.5.17 Fixing web sensor

9.5.17.1 Removing the Fixing Web Sensor

1) Slide out the fixing feeding unit.
2) Remove the fixing front cover.
3) Remove the fixing drive assembly.
4) Disconnect the connector [1], and detach the fixing web sensor [2].

9.5.18 Fixing shutter sensor

9.5.18.1 Removing the Shutter Sensor

1) Remove the fixing upper unit.
2) Remove the screw [1], and detach the shutter sensor support plate [2].
[2]
3) Remove the shutter sensor [1] from the shutter sensor support plate.
[1]

9.5.19 Fixing shutter motor

9.5.19.1 Removing the Shutter Motor

0009-2913
[2]
[1]
F-9-130
0009-2915
[1]
F-9-131
F-9-132
0009-2914

Hide quick links: