Removing The Scanning Lamp - Canon iR6570 series Service Manual

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

3]
1]
5.4.3.8 Removing the CCD Unit Cover
1) Remove the 9 screws [1], and detach the CCD unit cover [2].

5.4.3.9 Removing the Scanning Lamp

1) Disconnect the connector [1], and free the cable [2] from the cable
guide [3] and the snap band [4].
2) Open the ferrite core [5] to detach. (100/230V machine)
2]
1]
F-5-56
0008-7626
[1]
[1]
[2]
F-5-57
[1]
F-5-58
0008-7627
[2]
[5]
[4]
When replacing the scanning lamp, be sure to fit the removed ferrite
core to the new lamp. (100/230V machine)
3) Slide the No. 1 mirror base [1] to the right so that it matches against
the cut-off [2] of the frame.
When detaching the No. 1 mirror base, be sure to hold it by the bend [A]
on the mirror stay.
[1]
[2]
4) Remove the 2 screws [1], and detach the scanning lamp [2].
Chapter 5
[1]
[3]
F-5-59
[2]
[A]
F-5-60
5-23

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ir5570Ir5570n

Table of Contents