Chapter 9
[1]
If you need to temporarily put aside the removed delivery unit, be sure
to orient it as shown. You can damage the separation claws if you place
it with the claws against the floor.
4) Remove the E-ring [1], O-ring [4], and bushing [3] (at the front), and
then remove the E-ring [4], gear [5], E-ring [6], and bushing [8] (at
the rear); then, detach the outside delivery roller [9].
9-32
[3]
[2]
F-9-71
F-9-72
[4]
9.5.6 Internal Delivery Roller
9.5.6.1 Removing the Inside Delivery Roller
1) Remove the fixing feeding unit from the machine.
2) Detach the lower separation claw support plate.
Note:
Of the following steps, steps 3) through 6) are performed at the front
of the machine:
3) Disconnect the 3 connectors [1], and free the harness from all clamps;
then, remove the 3 screws [2], and detach the motor support plate [3].
[2]
[1]
4) Disconnect the 3 connectors [1], and remove the 3 screws [2]; then,
slide out the fixing heat discharge fan assembly [3] toward the
outside.
[8]
[7]
[6]
[9]
[5]
[3]
[2]
[1]
F-9-73
0009-4876
[1]
[2]
[2]
[3]
F-9-74