Download Print this page

Canon iR5570 Service Bulletin

Copier b/w hardware
Hide thumbs Also See for iR5570:

Advertisement

Quick Links

Model:
iR5570
iR6570
Location:
Scanner Mount Assembly
Subject:
Measures against white lines in sub scanning direction due to deformation of Primary Fan Duct
Detail:
<Symptom>
White lines occur in the sub scanning direction.
<Cause>
A Primary Fan Duct [FL2-3018] is partially warped to the Primary Corona Assembly (to the left) [1]. Then, a Cleaner
Pad stops during its operation to cause white lines in the sub scanning direction.
<Factory work>
Add a tap hole to the position a scanner stays in the copier and fix the Primary Fan Duct (FL2-3018) with a screw so
as to prevent it from warping.
Service Bulletin
Issued by Canon Europa N.V.
P-1
AP kit is dismounted
[1]
Warped position of Primary Fan Duct
Ref No.:
iR6570-013
(F1-T01-0M5-10039-01)
Date:
January, 2006
Copier B/W
Hardware
(1/5)

Advertisement

loading

Summary of Contents for Canon iR5570

  • Page 1 Service Bulletin Copier B/W Issued by Canon Europa N.V. Hardware Model: Ref No.: iR6570-013 iR5570 (F1-T01-0M5-10039-01) iR6570 Date: January, 2006 Location: Scanner Mount Assembly Subject: Measures against white lines in sub scanning direction due to deformation of Primary Fan Duct Detail: <Symptom>...
  • Page 2 iR6570-013 Service work: When the symptom above occurs, carry out the following procedure. 1. Refer to "Service manual" > "Image formation" > "7.10.3 Primary Charging Assembly", remove the Primary Corona Assembly from the copier and check if the part [2] of Primary Fan Duct is warped to the Corona Assembly (to the left).
  • Page 3 iR6570-013 4. Prepare the Primary Fan Duct, affix two-sided tape to the Duct as shown in [5] and then remove the release paper from the tape. Note: Affix two-sided tape to the position as shown in [6], not lying off the edge of the mold and within 0.5mm from the edge (OK for extending onto the molt plane).
  • Page 4 iR6570-013 6. Affix the side of the Duct with the two-sided tape (at step 4) to the upper Sheet Metal. Be sure that the Sheet Metal is straight as shown in [10] not warped as shown in [9]. 7. Mount the AP-kit on the copier and make sure that the Primary Fan Duct does not extend off the Primary Corona Rail of the AP-kit as shown in [11].
  • Page 5 Affected machines: iR6570 120V KHN00372 and later iR5570 120V KHT01604 and later iR6570 230V KHP00011 and later iR5570 230V KHU00014 and later (5/5)

This manual is also suitable for: