Chapter 15
Code
E604
E609
E610
E674
E710
E711
E713
E717
15-10
Description
0007 [Cause] ICC-Profile compatible with the PDL type
does not exist in /BOOTDEV/PDL.
[Description] beginning of oclibroot; the PDL team
function is called and determined
[Timing] once at start-up of Bootable
01XX /DOSDEV is faulty.
02XX /FSTDEV is faulty.
03XX /DOSDEV2 is faulty.
04XX /FSTPDEV is faulty.
05XX /DOSDEV3 is faulty.
06XX /PDLDEV is faulty.
07XX /DOSDEV4 is faulty.
08XX /BOOTDEV is faulty.
09XX /DOSDEV5 is faulty.
FFXX There is an error in a partition that cannot be
identified.
The image memory is faulty or inadequate.
0000 The memory is inadequate for the model.
The hard disk is faulty.
0008 At time of start-up, the HDD fails to reach a
specific temperature within a specific period of
time.
0009 At time of a sleep shift, the temperature is below a
specific level.
The HDD encryption key is faulty. (hardware composition error, initialization error, ID key error, ID
processing error)
0001 There is no encryption board.
0002 The memory configuration is inadequate for the
use of encryption.
0101 The attempt to initialize the memory used for
storage of the key has failed.
0102 The attempt to initialize the encryption processing
area has failed.
0201 There is an error in the encryption processing area.
0202 There is an error in the encryption processing area.
0301 The attempt to create an ID key has failed.
0302 A fault has been detected in the encryption key.
0303 A fault has been detected in the encryption key.
0401 An error has been detected at time of coding.
0402 An error has been detected at time of decoding.
There is a fault in the communication between the fax controller PCB (2-line) and the main controller
PCB.
0001 An attempt to set fax device mode has failed.
There is a fault in IPC initialization.
0001 At time of power-on, the communications IC on
the main controller PCB does not become ready
within 3 sec after start-up.
0002 At time of power-on, the communications IC on
the DC controller PCB cannot be initialized.
There is a fault in the IPC communication.
0001 After power-on, the occurrence of an error has been
written 4 times in 1.5 sec to the error register of the
communications IC on the main controller PCB.
0002 After power-on, a fault has been detected by the
communications IC on the DC controller PCB.
There is a fault in the communication with the finisher.
0000 A fault has been detected in the communications IC
on the finisher side.
There is a fault in the communication with the NE controller.
After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Remedy
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- See details for E602.
- Add memory.
- Replace the hard disk.
- Replace the DC controller PCB.
- Check the hardware composition.
- Turn off and then on the main power.
- Turn off and then on the main power.
This error will reset all content on the HDD.
- Turn off and then on the main power.
- Check the connection of the cable between the
fax controller PCB (2-line) and the main
controller PCB.
- Replace the ROM DIMM of the fax controller
PCB (2-line).
- Replace the fax controller PCB (2-line).
- Replace the main controller PCB.
- Check the connection of the cable.
- Check the connection of the cable.
- Check the connection of the cable.
- Replace the finisher controller PCB.
- Replace the DC controller PCB.