Adjusting The Position Of The Fixing Web Solenoid (Sl9); Upper Separation Claw; Removing The Upper Separation Claw - Canon iR6570 series Service Manual

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

cover [2]; then, remove the 2 screws [3], and detach the fixing
feeding unit middle cover [4].
[3]
[3]
[4]
6) Disconnect the connector [1], and remove the 2 screws [2]; then,
detach the fixing web solenoid [3].
[1]
[3]
9.5.22.2 Adjusting the Position of the Fixing Web
Solenoid (SL9)
a. If the fixing web is new,
Turn the screw [2] to adjust the position of the solenoid so that the
shift distance of the drive lever [1] is 8.6 mm.
[2]
b. If the fixing web has been used at all,
Before removing the solenoid, check the position of the drive lever
as found when the solenoid goes on. After replacing the solenoid,
turn the screw [2] so that the drive lever [1] is located as it was before
the replacement.
[1]
[2]
[1]
F-9-143
[2]
F-9-144
0009-4881
[1]
8.6mm
F-9-145
[2]

9.5.23 Upper Separation Claw

9.5.23.1 Removing the Upper Separation Claw

1) Open the front cover.
2) Slide out the fixing feeding unit.
3) Open the delivery unit cover [1].
4) While lifting the spring [1], detach the upper separation claw [2].
[1]
Chapter 9
[1]
A
F-9-146
0009-2879
[1]
F-9-147
[2]
F-9-148
9-45