9) Free the AC harness [1] from the harness guide [2].
10) Remove the 2 screws [1], and free the AC harness from the clamp;
then, detach the AC inlet [2].
[1]
11) Remove the screw [1], and detach the fixing heater unit stopper plate
[2].
[2]
[1]
9-38
[2]
[1]
F-9-105
[1]
[2]
F-9-106
[2]
F-9-107
F-9-108
Do not loosen or remove the 2 screws [1] (glued in place).
[1]
12) Remove the shutter [1], and move the fixing heater unit [2] in the
direction of the arrow to detach.
[1]
[2]
The shutter is thin (0.5 mm thick) and, therefore, can easily deform.
Deformation will cause it to interfere with the fixing roller, leading to
damage on the roller surface. Be sure to take full care during the work.
MEMO:
As wear grows, the shutter surface is likely to become discolored
because of heat or can show scratches. The fact, however, will not affect
the performance of the shutter.

9.5.11 Fixing Cleaning Belt

9.5.11.1 Removing the Fixing Web

1) Open the front cover.
2) Slide out the fixing feeding unit.
3) Remove the screw [1], and detach the fixing upper cover [2].
F-9-109
F-9-110