Canon iR6570 series Service Manual page 609

Hide thumbs Also See for iR6570 series:
Table of Contents

Advertisement

Sub-item
Description
DFDST-L1
Use it to adjust the dust detection level for the ADF (sheet-to-sheet
correction).
A higher setting will cause the machine to be more sensitive to finer particles
of dust.
setting: 0 to 225
(Setting the item to '0' will disable the dust detection mechanism.)
DFDST-L2
Use it to add the dust detection level for the ADF (post-job detection).
A higher setting will cause the machine to detect finer particles of dust.
setting: 0 to 255
(Setting the item to '0' will disable the dust detection mechanism.)
ENVP-INT
Use it to set the interval at which a log is collected for the machine inside
temperature/humidity and fixing temperature.
COPIER>FUNCTION>MIS-P>ENV-PRT and
COPIER>DISPLAY>ENVRNT
setting
0 to 480 (default: 60; in min)
BASE-SW
Use it to switch from MEAP-full model to base model.
setting
0: off (based model)
1: on (full model)
SC-L-CNT
Use it to change the threshold level of the paper size (large/small) for the scan
counter.
setting
0: count B4 as small size (default)
1: count B4 as large size
DHON-TM
Use it to set the timing at which drum heater goes on in sleep mode (with
reference to clock time).
setting: 0 to 24 (default: 0: in hr)
DHON-IVL
Use it to set the timing at which the drum heater goes on in sleep mode (with
reference to time after a shift to sleep mode).
setting: 0, 15 to 1440 (default: 0; in min)
DHOF-TM
Use it to set the timing at which the drum heater goes off in sleep mode (with
reference to clock time).
setting: 0 to 24 (default: 01; in hr)
DHOF-IVL
Use it to set the timing at which the drum heater goes off in sleep mode (with
reference to clock time).
setting: 0, 15 to 1440 (default: 0; in min)
CBLTINVL
Use it to change the number of times the fixing web solenoid goes on.
Make use of it when image faults occur as the result of soiling on the pressure
roller.
Setting
0: normal (default)
1: twice normal
PO-CNTMD
Use it to select the number of times the potential control mechanism goes on.
0: once at power-on
1: once at power-on and, in addition, 10 and 60 min thereafter (simplified
potential control mode)
2: once at power-on and, in addition, 10 and 60 min thereafter (normal
potential control mode; default)
W-CLN-P
Use it to set the interval at which the primary charging wire is automatically
cleaned.
setting: every 100 to 2000 (sheets; default at 2000)
IDL-MODE
Use it to select idle rotation mode for the developing assembly.
0: fix to low humidity mode (off)
1: environment control (default)
2: fix to normal temperature/humidity mode (idle rotation for 120 sec)
3: fix to high humidity mode (idle rotation for 300 sec)
4: power save mode
FSPD-S1
Use it to select fixing enhancement mode.
0: normal (default)
1: fixing enhancement mode
2: not used
TSPLY-SW
Use it to switch over toner supply sequence.
0: environment control (default)
1: fix to low humidity mode (on for 1.4 sec, off for 1 sec)
2: fix to normal temperature/humidity mode (on for 1.5 sec, off for 1 sec)
3: fix to high humidity mode (on for 3 sec, off for 2 sec)
SCANSLCT
Use it to enable/disable the function used to compute the scan area from the
selected paper size.
setting
0: off (determine scan area by original detection)
1: on (determine scan area by paper size)
OHP-TEMP
Use it to switch over control temperature for transparency mode.
setting
0: normal (default); 1: -5 deg C; 2: -10 deg C; 3: -15 deg C; 4: -20 deg C
COPIER > OPTION > BODY
Chapter 16
Level
1
1
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
16-41