Programming Output Devices - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

STOP (STP):

Programming Output Devices

1. From data field programming mode, press #93 to display the "ZONE PROG?" prompt.
2. Press 0 (NO) to each menu option until the "RELAY PROG" prompt appears.
(YES).
While in this mode, press
screen.
Enter Relay No.
(00=Quit)
01 A EV ZL ZT P
STT 0 0 00 00 0
01
STOP 0 00 00 0
01 Relay Action
No Response
01 Start Event
Not used
– 104 –
The "ZONE TYPE" option functions independently of the "EVENT/ZONE LIST"
combination.
b.PARTITION No. (P). The device's "Start" ZONE TYPE/SYSTEM
OPERATION may be limited to an occurrence on either one partition (1-8)
or any partition (0).
The "STOP" programming determines when and under what conditions the
device will be de-activated. The following options are available:
1)
a.RESTORE ZONE LIST (ZL). If a "ZONE LIST" is used as the "Stop"
event, the device will de-activate when all the zones in that list restore from
a previous fault, trouble, or alarm condition. This will occur regardless of
what is programmed to "START" the device; therefore, a "RESTORE ZONE
LIST" would normally only be used when a "ZONE LIST" is used to start the
device.
2).
a.ZONE TYPE/SYSTEM OPERATION (ZT). Instead of using a "RESTORE
ZONE LIST", a specific zone (response) type or system operation action can
be selected to de-activate the device.
If a specific "ZONE TYPE" is chosen, any zone of that response type that
restores from a previous alarm, trouble, or fault condition will cause the
device to de-activate.
If a "SYSTEM OPERATION" is chosen, that operation will cause the device
to de-activate.
OPERATION" are listed in "Programming Relays & Powerline Carrier
devices" later in this section, and in the Programming Form.
b.PARTITION No. (P). The device's "Stop" Zone Type/System Operation may
be limited to an occurrence on either one partition (1-8) or any partition (0).
Enter the relay (output device) identification number 01-96. This is a
01
reference number only, used for identification purposes. The actual
module address and relay number is programmed in the last two
prompts. Press
The keypad will display a summary START screen. Press
continue.
A ZL ZT P
The keypad will display a summary STOP screen.
continue.
The Relay Action is the way in which the relay will respond when
activated by the "start" event. Enter the desired action for this relay
as follows: 0=not used; 1=closed for 2 secs.; 2=stay closed; 3=pulse
on/off
A relay may be activated either by an Event used in conjunction with
a Zone List, or by a Zone Type/System Operation.
Event/Zone List combination, enter the event code as follows: 0=not
used; 1=alarm; 2=fault; 3=trouble; 4=restore
If not using a Zone List to activate the relay, enter 0. Press
continue.
The different choices for "ZONE TYPE" and "SYSTEM
to advance to next screen. Press # to backup to the previous
.
Press 1
to
Press
to
If using an
to