Wiring the 4285
VIP Module
–44–
2. When mounting the VIP Module outside the cabinet, use the screw holes at
the rear to mount horizontally or vertically (double sided adhesive tape may
be used, if preferred). You can bring wires out from the side or back (a round
breakout is also available on the back).
3. Affix the 4285 connections label (supplied separately) to the inside of the VIP
Module's cover if the cover is used. Otherwise, affix the label to the inside of
the control cabinet's door.
The 4285 is wired between the control panel and the premises handset(s). It
listens for multifrequency (DTMF) tones on the phone line and reports them to
the control panel. During on-premises phone access, it powers the premises
phones; during off-premises phone access, it seizes the line from the premises
phones and any answering machines. Wire as follows:
1. Make 12V (+) and (–) and data in and data out connections from the VIP
Module to the control*, using the connector cable supplied with the VIP
Module (see below).
RED
BLACK
GREEN
YELLOW
* These are the same connections as for remote keypads.
2. Insert the keyed connector at the other end into the mating header on the
VIP Module.
2. Connect terminals 1 through 5 on the VIP Module as shown in the VIP
Module Connections diagram.
You must use an RJ31X jack (CA38A in Canada) with a direct-connect cord and
make all connections exactly as shown. If the leads on the direct-connect cord are
too short to reach their assigned terminals, splice additional wires to them, as
required.
4285 Terminal
1. Phone In (Tip)
2. Phone In (Ring)
3. Phone Out (Tip)
4. Phone Out (Ring)
5. Ground
6. Audio Out 1
7. Audio Out 1
6 (AUX +)
7 (AUX -)
8 (DATA IN)
9 (DATA OUT)
Terminal Block Connections
Connects to:
Terminal (26) on control.
Terminal (27) on control.
BROWN lead from direct-connect cord.
GREY lead from direct-connect cord.
Earth ground terminal (30) on control.
Future use
Future use