– 82 –
USER BYPASS OF TAMPER FAULTS INSTEAD OF
1*39
INSTALLER ONLY BYPASS
1 = yes
0 = no (ANPI requirement)
MAX. NUMBER OF ZONES THAT CAN BYPASSED PER
1*40
PARTITION
(partition-specific)
01-15, 00 = no restriction (must not be 00 for ANPI compliance)
BYPASS/UNBYPASS ZONES WHEN ARMED
1*41
1 = able to bypass and unbypass non-fire zones while the system is
armed.
0 = zone bypass during the armed mode is not desired.

CALL WAITING DEFEAT

1*42
1 = the panel defeats call waiting on the first attempt (DO NOT enable
unless call waiting is being used.
0 = no call waiting defeat

PERMANENT KEYPAD DISPLAY BACKLIGHTING

1*43
(partition-specific)
1 = backlighting for the keypad display remains on at all times.
0 = display remains unlit unless a key is pressed. The backlighting then
turns off again after a period of keypad inactivity. Note that when a
key is pressed, display backlighting turns on for all keypads in that
partition.

WIRELESS KEYPAD TAMPER DETECT

1*44
1 = enable tamper detection on wireless keypad (ANPI requirement)
0 = tamper detection is not desired.
If this feature is enabled, any attempt to tamper by means of many trial
entries at a wireless keypad will be blocked by the control panel. If more
than 40 key depressions are received without a valid sequence (arm,
disarm, etc.), the Control panel will disable the wireless keypad. The
inhibit is removed once a valid key sequence is received from a wired
keypad.
EXIT DELAY SOUNDING
1*45
1 = beeps from the keypads during exit delay occur
0 = no keypad sound during exit delay
AUXILIARY OUTPUT MODE
1*46
0 = ground start output is required
1 = the auxiliary output is used to produce an open/close trigger
(produced only if all partitions are armed);
2 = the auxiliary output will be used to produce keypad-like sounding at
an auxiliary sounder (ex. PAL328N) This option applies only to the
partition set in field *15.
3 = AAV module is being used
NOTE: Only one of the above options can be active within a system.
CHIME ON EXTERNAL SIREN
1*47
1 = chime annunciation using the external alarm sounder.
0 = not desired
WIRELESS 5827/5827BD KEYPAD ASSIGNMENT
1*48
1-8 = the partition in which 5827/5827BD RF keypad is used
0 =
no RF keypad is used
SUPPRESS TX SUPERVISION SOUND
1*49
1 = disable trouble sounding for transmitter check-in failure
0 = audible trouble sounding is desired
(partition-specific)
(partition-specific)
[0]
[00]
|
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]
[0]