ADEMCO VISTA-120 Installation And Setup Manual page 98

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

020 Zone Response
Zone Disabled 00
For
series
serial number multiplex
devices only.
010 ACCESS POINT
(00-31)
010 ENTRY OR EXIT
020 Partition
020 Report Code
020 Input Type
RF Trans. RF:
Note that input types 4 & 5
are valid for certain
5800/5800EU series
transmitters only (ex. 5801,
5802, 5802CP, 5804EU&
5804). When using 5700
series transmitters, always
set the input type to 3 (RF).
The zone number of the
transmitter identifies
whether or not supervision is
required (ex. 5700 wireless
zone number 63 is not
supervised).
– 90 –
Each zone in a system must be assigned a zone type, which defines
the way in which the system responds to faults in that zone. Refer to
ZONE TYPE DEFINITIONS section for detailed definitions of each
zone type. Enter the zone response type for this zone. The screen
will automatically display the zone type for the number entered.
Press
Zone Types are as follows:
5800/5800EU
00 Assign for unused zones
RF
devices
or
01 Entry/Exit #1, burglary
02 Entry/exit #2,
03 Perimeter, burglary
04 Interior, follower, burglary
05 Trouble by day/Alarm by night, burglary
06
07
08
09
10
19
20
21
22
23
27
28
If response type 27 was selected, this prompt will be displayed.
Enter the access point to be controlled by the input type (00-31).
01
Select whether the access point is an entry or exit point.
0 = entry
0
1 = exit
Enter the partition number (1-8) in which this zone is located.
Enter the report code for this zone.
Enter the input device type as follows: 0 = not used; 1=wired;
3=supervised RF transmitter (RF type); 4=unsupervised RF
transmitter (UR type); 5=RF button type transmitter (BR type);
6=serial number polling loop device (SL type); 7=DIP switch type
polling loop device; 8=right loop of DIP switch type device;
9=keypad input (code + #73, code + #74); 10=PassPoint ACS
input.
Right loops refer to the use of the right loop on a 4190WH zone
expander module and/or 4278 series PIR, which allow hard-wired
devices to be monitored by the polling loop.
If wired, DIP switch polling loop, or 5700 series devices are being
programmed, after completing this entry, the summary display
appears. Press
the "Enter Zone Number" prompt for programming the next zone
into the system. If all zones are programmed, enter 00 and press
( ) to exit back to normal programming mode.
If either 5800 series RF or polling loop serial number devices are
being programmed, continue to the next prompt.
to accept entry.
24 hour silent alarm
24 hour audible alarm
24 hour auxiliary
Fire
Interior, delay, burglary
24 hour Trouble
Arm-stay
Arm-away
Disarm
No alarm response (ex. relay action)
Access Point
MLB Supervision (if VGM installed)
to continue. The display will now return to