Allow Disarm Outside Window If Alarm Occurs; Enable Goto For This Partition - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

AUTO-ARM DELAY
2*05
01-14
= (times 4 minutes) the time between the end of the arming
window and the start of auto arm warning time
00
= no delay is desired.
15
= auto arming is not desired.
AUTO-ARM WARNING PERIOD
2*06
01-15 = the time in one minute increments during which the user is
warned by a keypad sounding and display to exit the premises
prior to auto arming of the system.
AUTO-DISARM DELAY
2*07
01-14
= (times 4 minutes) the time between the end of the disarming
window and the start of auto disarming of the system.
00
= no delay is desired.
15
= auto disarming is not desired.
ENABLE FORCE ARM FOR AUTO-ARM
2*08
1 = the system should automatically bypass any faulted zones when it
attempts to auto arm.
0 = otherwise
OPEN/CLOSE REPORTS BY EXCEPTION
2*09
1 = open/close reports sent only if the openings/closings occur outside
the arm and disarm windows. Open reports will also be suppressed
during the closing window in order to prevent false alarms if the
user arms the system, then reenters the premises to retrieve a
forgotten item. Note that openings/closings are still recorded in the
event log.
0 = exception reporting is not desired.
Note: This field must be set to 1 if "No Opening" and "No Closing" reports
are to be sent (2*13, 2*14).
ALLOW DISARMING ONLY DURING ARM/DISARM
2*10
WINDOWS
1 = disarming of the system should be allowed only during the
arming/disarming windows or if the system is in alarm (if 2*11 is set
to "1"). Note that this applies only to operator level users. Installer,
Master and manager level users can disarm the system at any time.
0 = disarming can occur at any time.

ALLOW DISARM OUTSIDE WINDOW IF ALARM OCCURS

2*11
[1]
1 = allow the system to be disarmed outside the programmed disarm
(opening) window if an alarm has occurred.
0 = allow disarming only during the disarm window, regardless of
system status.
Used only if field 2*10 (partition-specific field) is set to 1. If field 2*10 is
set to 0 for a partition, this field (2*11) has no effect for that partition.

ENABLE GOTO FOR THIS PARTITION

2*18
(partition-specific)
1 = this partition is to be accessed from another partition's keypad using
the GOTO command.
0 = otherwise
(partition-specific)
(partition-specific)
(partition-specific)
(partition-specific)
(partition-specific)
(partition-specific)
[15]
|
[15]
|
[15]
|
[0]
[0]
[0]
[0]
– 85 –