Output Relays and Powerline Carrisr Devices
1. With at least one 2-line Alpha keypad (5137AD or 6139) connected to the
Partition 1 keypad terminals on the control, power up the system
temporarily. If you had previously connected the AC hnsformer
to the
controlpanel, you need only plug in the transformer (to 120VAC outlet)to
power up the system.
2.
Enter the programming mode by keying the following on the Alpha
keypad
Installer code (41 12) +8+ O + O.
3. Press *7.
POWERLINE
CARRIER
DEVtCE HOUSE ID.
u
Enter House ID 1-15 for Powerline Carrier devices,as follows:
0=~l=B,2=C,3
=D,4=E,5=F,6
=G,7=H,8=I,9
=J,#+10=~
#+ll=L,
#+12=
M,#+13=N,
#+ 14=0, #+15=P.
Default is O.
The House ID must match the House ID set on the powerline carrier
devices.The unit ID for these devicesis 1-8 dependingon which deviceis
being programmed. For example, device #1 must be set to unit ID 01,
device#2 to unit ID 02, etc.
4.
Press *80.
Note that this is an interactive progr amming mode. It is
used to program all output devices used in the system (4229 or 4204
Relay modules, or Powerline Carrier devices).Refer to the Programming
Form worksheetfor *O Interactive Mode.
OutputDeviceDisplayss
II
Enter Device No.
(00 = Quit)
01 II
I
02
AEVZLZT
P
S1-roooool
I
II
02 Start Event
Not Used
o
I
m
I
02 Stare
Zn Typ
Not Used
00 I
Upon pressing *80, this screen will appear. Enter the Device Number 01 or
02 for a 4229, or 01, 02, 03, or 04 for a 4204, or 01-08 for Powerline Cfier
devices(or 00 to end these enties). press the [*I key to continue.
The [*] key is used to acceptan entry and advanceto the next prompt. The
[#] key is used to revert back to the last question to checkor change an
entry. Ress [*] to go forward again.
This
screen displays a summary of the current Device
START
programming
(for this example,device02 has been selected).
Press the [*] key to continue.
This screendisplays a summary of the current Device STOP programming.
Press the [*Jkey to continue.
Enter the desired deviceaction as listed below.Pressthe [*] key to continue.
O= No response
2 = CIoseand Stay Closed
1 = Closefor 2 seconds 3 = Continuous pulse on & off (1 sec ON, 1 sec OFF)
Enter the event to START the relay
O= Not US4
2 = Fault; 1 = Alarm; 3 = 'llouble
A zone list must be used in conjunctionwith an event. If a zone type/system
operationis to be used instead of an event, enter O.
Ress the [*] key to continue.
If a zone list will be used to START the relay action, enter the zone list
number (to be programmed in field *81): 1, 2, or 3. If not used, enter O.Ress
the [*I key to continue.
Jf a zone type or system operation will be used to START the deviceaction,
enter the appropriate two-digit code(seetable that follows). If not, enter 00.
Press the [*I key to continue.
47-