Example of Open/Close Exception Reporting & Scheduling
6:01PM
5:59AM
"Early opening" reports
will be sent if system
is disarmed before
opening window begins. during this time
expires.

Programming with #80 Scheduling Menu Mode

– 114 –
6AM
9AM
9:01AM
Opening Window
Auto-disarm delay begins .
No reports sent
Auto-disarm occurs after delay.
if system disarmed
(if auto-disarm is enabled)
window.
"Missed opening" reports will
be sent if user disarming has not * or disarmed if
occurred at expiration of
opening window.
"Late opening" reports will be
sent if disarm occurs after
the opening window expires
"Early closing" reports will be
sent if user arming occurs before
the closing window begins.
The #80 Scheduling Menu Mode is used to programme most of the scheduling
and timed event options.
To enter this mode, the system must first be in normal operating mode (all
partitions disarmed). Enter [Installer Code] + # + 80.
The following can be programmed while in this mode:
• Define time windows
• Assign open/close schedules to each partition
• Assign holiday schedules
• Programme time-driven events (for system functions and relay
activation)
• Assign access control schedules
Some scheduling features are programmed in data field programming mode
(installer code +800). The general programming mode scheduling fields are
listed below.
System Wide Fields:
Partition specific fields: 1*76
Event driven relay activation options are programmed using the #93 Menu
Mode, Relay Programming. These actions are in response to a programmed
action. However, relay activation can also be time driven, and thus be used
to initiate a desired action. Time driven relay activation options are
programmed using the #80 Scheduling Menu Mode. Refer to the Time Driven
Event Programming section for procedures.
3:59PM
4PM
Closing Window
No reports sent
if system armed*
during this time
window.
user reenters
premises.
1*74 -1*75 Relay timeout values
2*01-2*02 Summer time options
2*11
Allow Disarming outside window if
alarm occurs
Access control relay for this partition
2*05
Auto-arm delay value
2*06
Auto-arm warning time
2*07
Auto-disarm delay value
2*08
Force arm enable
2*09
Open/close reporting by exception
2*10
Restrict disarm only during windows
6PM
6:01PM
5:59AM
Auto-arm delay begins
Auto-arm warning begins.
Auto-arm occurs after
warning expires.
(if auto arm is enabled)
"Missed closing" reports
will be sent if user
arming has not
occurred at expiration
of closing window.
"Late closing" reports
will be sent if system
is armed after the
closing window