Disable Download Callback; Internal Clock Sync - ADEMCO VISTA-120 Installation And Setup Manual

Partitioned security system with scheduling
Hide thumbs Also See for VISTA-120:
Table of Contents

Advertisement

No. of SECONDS ADDED PER DAY
1*50
00-30 = the number of added seconds per day to correct the real-time
clock
No. OF SECONDS REMOVED PER DAY
1*51
00-30 = the number of subtracted seconds per day to correct the real-time clock
SEND CANCEL IF ALARM + OFF
1*52
1 = cancel reports to be sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
0 = cancel reports are to be sent within alarm sounder timeout period
only.

DISABLE DOWNLOAD CALLBACK

1*53
1 = disable the callback requirement for downloading
0 = require a callback

INTERNAL CLOCK SYNC

1*54
1 = use internal crystal for real-time clock
0 = use AC sync for clock
INTERNATIONAL DATE FORMAT
1*55
1 = the event log date format shall be DDMMYY.
0 = the date format shall be MMDDYY.
AC 60Hz or 50Hz
1*56
1 = AC mains frequency is 50Hz; 0 = AC mains frequency is 60Hz.
This selection is used to synchronise the real-time clock and X-10 devices.
ENABLE 5800 RF BUTTON GLOBAL ARM
1*57
1 = have the system arm/disarm in accordance with the button's user's
global arming settings.
0 = the button is not to be used to global arm the system (however, home
partition arming will still occur).
ENABLE 5800 RF BUTTON FORCE ARM
1*58
1 = allow the RF Button user to force bypass all faulted zones. When
attempting to arm the system, the keypad will beep once after
pressing the button if any faulted zones are present. If this feature
is enabled, the user should then press the button again within 4
seconds to force bypass those zones and arm the system.
0 = RF button forced bypassing is not desired.
SUPRESS STATUS LED OUTPUT WHEN ZONE 7
1*59
KEYSWITCH
OUTPUTS
1 =yes; 0 = no
ALARM VERIFICATION (audio)
1*60
1 = 2-Way Audio (AAV) is being used. Zone 5 is then not available as a
protection zone and is used only to provide feedback from the AAV
that its function has ended. Control will send Contact ID Event Code
606 to signal the central station equipment to ready itself for an
audio verification session.
0 = alarm verification is not being used.
DISPLAY "TAMP[e]R"
1*61
1 = yes, display "TAMPR" upon tamper condition
0 = no, display "CHECK" or "TRBL" depending on the state of field 1*07
TAMPER DETECT IN TEST MODE
1*62
1 = yes, terminate Test mode upon detection of tamper condition
0 = no, remain in Test mode upon tamper condition, display "FAULT"
SILENCE SOUNDER DURING AAV
1*66
1 = audio alarm verification (AAV) being used so that alarm sounders
and keypad sounders can be silenced when listening microphones
are on.
0 = AAV is not being used.
ENABLED
/
RETAIN
(partition-specific)
VOLTAGE
[0]
[0]
[0]
[0]
[0]
[1]
[1]
[0]
[0]
[0]
TRIGG.
[0]
[0]
[0]
[0]
– 83 –

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents