Zone Programming (this section has been revised from previous manuals)
Enter Programming mode [Installer Code] + 8 0 0 0. The following fields should be
programmed before beginning:
2*00: Number of Partitions; 1*32: RF Receiver Type.
Also, before programming wireless zones, the RF receiver must be enabled in Device
Programming Mode (procedure described later in Device Programming section).
Then press #93 to display "ZONE PROG?".
ZONE PROG?
1=Yes 0=No
PROGRAM TOOL?
0 = NO, 1 = YES
010 INPUT S/N: L
Axxx-xxxx
010 PROG AS BR: 3
A123-4567
ENTER ZN NO.
000 = QUIT
Zone Number Entered
020 ZT P RC In:L
00 1 00 RF:N
Press 1 to enter ZONE PROGRAMMING mode. The following
screens will appear. Press
display a previous screen.
If the system has been set up to use 5800 series RF, and a programme tool has not
been programmed, the following "PROGRAM TOOL" prompt will be displayed. If the
system has not been set up to use 5800 series RF or a programme tool has already
been programmed, the system will advance to the "ENTER ZN NO." prompt.
If a programme tool is being used, enter "1." If not using a tool, enter
"0". When a "0" is entered, the system will advance to the "ENTER
0
ZN NO." prompt.
If "1" is entered, the system will prompt for the unit's serial number.
Enter the programme tool's serial number using one of the following
methods:
a) Enter the 7-digit serial number for the transmitter
or
b) Press any button on the transmitter. The keypad should beep
three times and display the serial number of the tool.
In this example, the serial number is A123-4567. Once enrolled, the
upper left-hand button of the programme tool can be pressed to ready
the system for enrolling a device into the system.
The serial number for the programme tool will only remain in
the system until the programming mode is exited.
97 will not delete the tool.)
Press [*] to continue or press the [#] key to back the system up to the
"PROGRAM TOOL? " prompt.
Enter the zone number to be programmed (protection zones 001-128,
relay zones 601-696, † ECP device supervisory zones 800-831, system
020
supervision zones 988, 990,992 [duress], 997 or keypad panic zones
995, 996, 999). Press
† Programme relay zone numbers only if either of the following is true:
A: Supervision of a relay is desired (enter zone response type 5 or 19).
B: You are using only the relay output(s) of a 4208UXM or 4101
polling loop relay module without using a protection zone on the
module. This allows enrollment of the serial number of the relay
module, which is required for the control to identify and communicate
with the respective relay output. (If using a protection zone on these
modules, you need only enter the protection zone number for enrolling
the serial number. See Relay Programming V-PLEX ZONE # prompt.)
A summary screen for that zone will appear. ZT=Zone Type,
P=Partition, RC=Report Code, In:=the input type of device, and L=the
device's loop number to which the sensor is connected (some devices
can support more than one zone by means of individual loops (ex.
5801, 5804, 5804EU, 5816, 5816EU, 5817, etc.)
to display the next screen. Press # to
to accept entry.
(Entering
– 89 –