The following describes each format in greater detail.
3+1 and 4+1 Standard Formats
3+1 and 4+1 Expanded Formats
4+2 Format
Ademco Contact ID
Reporting Format
Ademco Expanded High Speed
Where:
SSS or
SSSS =
T t =
B b =
E A C =
L L B =
O =
*Zone numbers for:
Comprised of a 3- (or 4-) digit subscriber number and a single
digit report code (e.g. Alarm, Trouble, Restore, Open, Close, etc).
Comprised of a 3- (or 4-) digit subscriber number, and a two-digit
report code. The first digit is displayed on the first line, followed
by a second line where the first digit is repeated 3 (or 4) times
and followed by the second digit. This is the "expanded" digit.
Comprised of a 4-digit subscriber number and 2-digit report
code.
Comprised of a 4-digit subscriber number, 1-digit event qualifier
("new" or "restore"), 3-digit event code, 2-digit Partition No., and
3-digit zone number, user number, or system status number.
Comprised of 13 digits as follows: A 4-digit account number +
eight channels of zone information (1-8 or duress plus 9-15) +
one status channel, which identifies the type of events being
reported in the eight zone locations.
Report
Alarm
Trouble
Bypass
ACMains Loss
Low Batt
Open
Close
Test
Restore
Alarm
AC Mains Restore
LoBat Res.
Trouble Res.
Bypass Res.
Subscriber ID
A =
Alarm Code-1st digit
Z =
Typically Zone Number*-2nd digit
Trouble Code (1st & 2nd digits)
Bypass Code (1st & 2nd digits)
AC Mains Loss Code (1st & 2nd digits)
Low Battery Code(1st & 2nd digits)
Open Code-1st Digit
[ ] + [#], or [B] = 99;
[1] + [ ], or [A] = 95;
3+1/4+1
3+1/4+1
Standard
Expanded
SSS(S) A
SSS(S) A
AAA(A) Z
SSS(S) T
SSS(S) T
TTT(T) t
SSS(S) B
SSS(S) B
BBB(B) b
SSS(S) E
SSS(S) E
EEE(E) A C
SSS(S) L
SSS(S) L
LLL(L) L B
SSS(S) O
SSS(S) O
OOO(O) U
SSS(S) C
SSS(S) C
CCC(C) U
SSS(S) G
SSS(S) G
GGG(G)g
SSS(S) R
SSS(S) R
RRR(R) Z
SSS(S) R A
SSS(S) R A
R A R A R A (R A )A c
SSS(S) R L
SSS(S) R L
R L R L R L (R L )L B
SSS(S) R T
SSS(S) R T
R T R T R T (R T )t
SSS(S) R B
SSS(S) R B
R B R B R B (R B )b
C =
Close Code-1st Digit
U =
User Number (1st & 2nd digits)
G g =
Test Code (1st & 2nd digits)
R =
Restore Code (Alarm)1st & 2nd digits
R T t =
Restore Code (Trbl)1st & 2nd digits
R B b =
Restore Code (Byps)1st & 2nd digits
R A A C =
Restore Code (AC Mains)1st & 2nd digits
R L L B =
Restore Code (Bat)1st & 2nd digits
Duress = 92
4+2
Low Spd or
Express
SSSS AZ
SSSS Tt
SSSS Bb
SSSS EA C
SSSS LL B
SSSS OU
SSSS CU
SSSS Gg
SSSS RZ
SSSSR A A c
SSSS R L L B
SSSS R T t
SSSS R B b
[3] + [#], or [C] = 96;