Installing The Back-Up Battery
If necessary, refer to the FINAL POWER-UP PROCEDURE section for information
regarding battery size to use, etc.
1. Place the 12-volt back-up battery in the control cabinet.
2. Attach Red and Black wires on the battery connector cable as follows:
a. Red to the positive (+) battery terminal on the control board (see diagram above or
the Summary of Connections Diagram for location).
b. Black to the negative (–) battery terminal on the control board.
NOTE: A dual battery harness is supplied that allows two batteries to be wired in parallel
PRIMARY POWER
Supplied by a
transformer which
is rated at
16.5VAC, 40VA.
Caution must be
taken when wiring
this transformer to
the panel to guard
against blowing the
fuse inside the
transformer (non-
replaceable).
NOTE:
WHEN POWERING UP
THE PANEL, PLUG THE
TRANSFORMER IN BEFORE
CONNECTING THE BATTERY.
Figure 4: AC Power And Battery Connections
4300: If using 110VAC/60Hz (see page 37 for 220VAC connection) Powerline
Carrier devices, the 4300 transformer interface must be used instead of the
regular 1361 transformer. The 4300 supplies the control panel with AC, and also
sends control pulses through the premises electrical system to control the
Powerline Carrier devices. In Australia, use the XF10 and in Europe, use the
XM10E in addition to the normal 16.5VAC/40VA output transformer. See Final
Power Up section.
1. Connect terminals 1 and 3 (AC) and terminal 2 (Ground) of the 4300
transformer interface to control panel terminals 1, 2, and 30, respectively.
2. Run a 6-conductor cable between the 4300 and the panel. Splice this cable to
a 4142TR cable as shown below. Note that the white and yellow wires of the
4142TR must be spliced together.
4300 TRANSFORMER/INTERFACE
Earth
AC
Ground AC
2
1
115VAC
60Hz
TB1
TB1
TB1
-1
-30
-2
Figure 5: 4300 Transformer Connections
Do not connect the transformer to AC mains until you are instructed to do so later in
the manual.
Do not attach the connector cable to the battery terminals until you are instructed to
do so later in the manual.
for increased capacity.
BATTERY
TABS
Connect to
12VDC, 4AH
or 12VDC, 7AH
1
2
GEL CELL
BATTERY
CHARGING
VOLTAGE
13.7 VDC
Connect to
24hr. source
of AC mains
TRANSFORMER
16.5VAC, 40VA
ADEMCO No.1361
or 4300, XM10E, or
XF10 if X-10 DEVICES
WILL BE USED.
1 2 3 4 5 6 7 8 9
Sync Data Com
4
3
5
6
3
J8 CONNECTOR
4142TR CABLE
– 15 –