Keyswitch Setup

TO AUX POWER
(TERMINAL 6)
YELLOW
RED
(ARMED)
820ohms
RED
TO J7/OUT 2
TO J7/OUT 4
TO ZONE 7(– )
(TERMINAL 19)
BROWN
TO ZONE 7(+)
BLUE
(TERMINAL 20)
BROKEN LINES REPRESENT
INSTALLER WIRING CONNECTIONS
Figure 23a. Remote Keyswitch Wiring
IF USED.
1. OUT 1 IS NO LONGER
USABLE FOR OPEN/CLOSE
OR GROUND START (SEE
FIELD 1*46).
2. OUT 2, 3, 4 CAN STILL BE
USED TO PROVIDE ALARM
STATUS INDICATIONS OR
TO OPERATE A KEYSWITCH
(SEE FIELD *15).
TO AUX POWER +
TERMINAL 6
(10mA CURRENT DRAIN)
Figure 22. Remote Keypad Sounding Connections
If using an optional Remote Keyswitch for remote arming and disarming of the
system, its switch must be connected to Zone 7 and its Ready and Armed status
LEDs must be connected to the trigger outputs and programmed in order to
become operational.
Note that a zone 7 keyswitch may be used in one partition only.
The keyswitch must be connected to Zone 7, which is then no longer available as
a protection zone. A momentary short across this zone will arm the partition in
the "AWAY" mode. If the short is held for more than 3 seconds, the partition will
arm in the "STAY" mode. After the partition has been armed, the next time Zone
7 is shorted, the partition will disarm.
1. Connect the 4146 keyswitch's normally open momentary switch to Zone 7.
2. Connect a 2k EOL resistor across the switch regardless of whether or not
zones 2-8 are selected to use EOL resistors.
3. Connect the keyswitch Armed and Ready LEDs to the J7 connector as shown.
4. Connect an optional closed circuit tamper switch (ex. No. 112) in series with
zone 7.
5. Assign the keyswitch to its appropriate partition in programme field *15.
Enable open/close reporting (user #0) for the keyswitch in field *40 (if
desired).
NOTE:
When the keyswitch is
removed from the wall, the
WHITE
tamper switch will open causing
GREEN
a fault (trouble or alarm) on
(READY)
zone 7 and causing the panel
to disable keyswitch operation
820ohms
until the partition is disarmed
from a keypad.
BLACK
TAMPER SWITCH
BROWN
LOCK SWITCH
(NORMALLY OPEN)
BLUE
2K EOLR
4142TR CABLE
BLACK
AMSECO PAL-328N
PIEZO SOUNDER
+
RED
LED indications are defined as follows:
Green Red
Off
Off
On
Off
Off
On Steady
Off
Slow Flash
Off
Rapid Flash
J7 CONNECTOR
GRAY
YELLOW
WHITE
RED
GREEN
BROWN
BLUE
BLACK
Meaning
Disarmed & Not Ready
Disarmed & Ready
Armed Away
Armed Stay
Alarm Memory
– 51 –