COMMON AREA 3 PARTITION

1*17
1-8 = common area 3 partition
0
= none
AFFECTS COMMON AREA 3
1*18
1 = this partition affects common area 3. This partition will cause
common area 3 to disarm when this partition disarms.
0 = this partition does not affect common area 3
ARMS COMMON AREA 3
1*19
1 = arming this partition causes the system to attempt to arm the
common area 3 partition automatically. Can only arm common area
3 if all other affecting partitions are armed. To enable this function,
field 1*12 (partition-specific) must also be enabled.
0 = does not apply

AUTO BYPASS FAULTED EXIT ROUTE ZONES

1*20
1 = enable automatic bypass of exit route zones remaining faulted at the
end of the exit delay. Must be selected only if field *07 is enabled.
0 = automatic bypass function is not desired
EXIT DELAY RESET
1*21
1 = reset Exit Delay to 60 seconds after door is closed
0 = Exit Delay not to be reset
CROSS ZONING PAIR ONE
1*22
001-128
= first pair of zones which must both be faulted within a five
minute period to cause an alarm
000, 000 = disable
CROSS ZONING PAIR TWO
1*23
001-128
= second pair of zones which must both be faulted within a
five minute period to cause an alarm
000, 000 = disable
CROSS ZONING PAIR THREE
1*24
001-128
= third pair of zones which must both be faulted within a five
minute period to cause an alarm
000, 000 = disable
CROSS ZONING PAIR FOUR
1*25
001-128 = fourth pair of zones which must both be faulted within a five
minute period to cause an alarm
000, 000 = disable
PANIC BUTTON OR SPEED KEY
1*26
(partition-specific)
01-32 =
the number of the multi-keystroke macro associated with
each of the lettered keys on the keypad
00
=
each of the lettered keys (with exception of the D key, where
00 signifies "not used") which shall remain single press panic
keys.
FIELD 1*31 RF TRANSMITTER CHECK-IN SUPERVISION
1*27
INTERVAL TO BE MULTIPLE OF 1 HOUR INSTEAD OF
2 HOURS
1 = 1 hour (must be 1 hour for CENELEC compliance)
0 = 2 hours
RF TX LOW BATTERY SOUND
1*28
0 = audible beep and display annunciation upon RF transmitter low
battery condition is desired only in disarmed state.
1 = audible beep and display is desired in both armed and disarmed
states.
(partition-specific)
(partition-specific)
A
[0]
[0]
[0]
[0]
[0]
| |
| |
| |
| |
| |
| |
| |
| |
|
|
|
|
B
C
D
[0]
[0]